Click here for a block diagram of a typical application.

RS-1000

 

1 for N

Frequency Range

Insertion Loss dB (2)

Isolation dB   (3)

VSWR   (50 Ω)

Switching Time msec

Control Interface Normal (4)

RS-1000-4-IF

1 for 4

10 - 200 MHz 

2.0

 80

 1.3:1

 

 <200 

 

   

 RS-232/422

 

RS-1000-5-IF

1 for 5

RS-1000-6-IF

1 for 6

RS-1000-8-IF

1 for 8

RS-1000-4-LB

1 for 4

 

950 - 2150 MHz

 

 

 5.0

 

 

 70

 

 1.5:1

 

 <200

 

 RS-232/422

RS-1000-5-LB

1 for 5

RS-1000-6-LB

1 for 6

RS-1000-8-LB

1 for 8

Solid State Switches

 

RS-1001

 

1 for N

Frequency Range

Insertion Loss dB (2)

Isolation dB   (3)

VSWR   (50 Ω)

Switching Time msec

Control Interface Normal (4)

RS-1001-4-LB

1 for 4

 

950 - 2150 MHz

 

5.0 

80  

1.3:1 

<200

RS-232/422 

RS-1001-5-LB

1 for 5

RS-1001-6-LB

1 for 6

RS-1001-8-LB

1 for 8

RS-1001-4-MW

1 for 4

 

0.5 - 18 GHz

 

2.0 

80 

1.5:1 

<200 

 RS-232/422 

RS-1001-5-MW

1 for 5

RS-1001-6-MW

1 for 6

RS-1001-8-MW

1 for 8


NOTES:

1. The RS-100X consists of two modules, one transmit, one receive.

2. Insertion Loss is specified end-to-end.

3. Isolation is specified end-to-end.

4. The control algorithm is set via dipswitch. Optional Ethernet control is available.

5. 75 ohm impedance available.

 

 